50 Watt (LN50W Series)
Constant Current or Constant Voltage
0-10V Dimmable/Non-Dimmable
UL Type HL for Hazardous Locations
50W led driver UL Type HL for Hazardous Locations

Output Voltages 9VDC - 142VDC
Output Watts 50W Max.
Output Currents 350mA - 2800mA
Input Voltage Range 90 - 305VAC, 47-63Hz
Selectable CC output Choose from ≅ 50% ~ 100% of the standard rated output
Dimming Options 0-10V dimming 5%-100%
Number of Outputs 1
UL, cUL, CE UL8750 Type HL, CSA 22.2, EN61347
Inrush Current <50 Amps @ 25C, 277Vac, cold start, Full Load
Typical Efficiency 88% @ 230Vac, full load
Power Factor ≥0.90 @ ≥60% Load, 120Vac/230Vac; ≥88% load, 277Vax
Operating Temp -30C to +60C
Storage Temp -40C to +85C, 5~95% RH
MTBF 478,000 hours @ Full Load per MIL-217F Notice 2 at 25C
Shock/Vibration 5~55Hz/2g, 30 minutes
Safety UL8750 Type HL, EN61347, CSA 22.2 compliant
EMC FCC, 47FR Part 15 Class B and EN55015, EN61000-3-2 & EN61000-3-3 Class C
Mounting/Connection Case mounting holes with flying leads
Weight 198 Grams (7.0 oz) typical


UL Document